Claind – Nitrogen Generator – NiGen LCMS

  • AUSTRALIA

    Benoit Fissot, General Manager, Technology, Australia & New Zealand

    DKSH Australia Pty Ltd
    1 Beyer Road
    3195 Braeside VIC
    Australia

    1800 010 114 (hotline)

    Email

  • CAMBODIA

    Len Sena, Business Development Manager

    DKSH (Cambodia) Ltd
    Corner Preah Monivong Boulevard and Street 484
    Phnom Penh
    Cambodia

    +855 87 887 883

    Email

  • JAPAN

    DKSH Japan K.K. Technology

    DKSH Japan K.K.
    3-4-19 Mita, Minato-ku
    108-8360 Tokyo
    Japan

    Email

  • KOREA

    Gyerim Kim, General Manager

    DKSH Korea Ltd.
    3rd Floor, Zen building, 152 Dogok-ro, Gangnam-gu
    06261 Seoul
    Korea

    +82 2 2192 9723

    +82 2 2192 9595

    Email

  • LAOS

    Julien Moret, General Manager, Laos, Myanmar & Cambodia

    DKSH Laos Company Ltd.
    3rd Floor, Vientiane Center Office Building Khouvieng Road,
    Sisattanak District
    Vientiane Capital
    Laos

    +856 21 221 023

    +856 21 453 555

    Email

  • MALAYSIA

    Jasmine Keller, Assistant General Manager, Scientific Solutions

    DKSH Technology Sdn. Bhd.
    B-11-01, The Ascent, Paradigm, No. 1, Jalan SS7/26A, Kelana Jaya
    47301 Petaling Jaya, Selangor
    Malaysia

    +60 3-7882 6285

    Email

  • NEW ZEALAND

    Benoit Fissot, General Manager, Technology, Australia & New Zealand

    DKSH New Zealand Limited
    72 Apollo Drive
    0632 Mairangi Bay, Auckland
    New Zealand

    0800 951 010

    Email

  • PHILIPPINES

    Camilo Umlas, General Manager

    DKSH Philippines Inc.
    8th Floor Cyber Sigma, Lawton Ave., McKinley West,
    Fort Bonifacio
    1634 Taguig City
    Philippines

    +63 2 8548 3200

    Email

  • SINGAPORE

    Monica Wan, General Manager

    DKSH Singapore Pte Ltd
    625 Lorong 4 Toa Payoh, #03-00
    319519 Singapore
    Singapore

    +65 6962 3121

    +65 6273 1503

    Email

  • TAIWAN

    Whitney Lin, Manager

    DKSH Taiwan Ltd.
    10th Floor, No.22, Lane 407, Section 2, Tiding Boulevard,
    Neihu District
    114-93 Taipei
    Taiwan

    +886 2 8752 7935

    Email

  • VIETNAM

    Nguyen Thi Xuan Mai, Senior Manager, National Sales

    DKSH Technology
    5th Floor, Viettel Complex, 285 Cach Mang Thang Tam Ward 12,
    District 10/6th Floor, Peakview Tower,
    36 Hoang Cau O Cho Dua Ward
    70000 Ho Chi Minh City / Dong Da District, Ha Noi
    Vietnam

    +84 28 3812 5806 ext 89604

    +84 8 3812 5807

    Email

  • Claind NiGen LCMS Factsheet


  • Designed to satisfy the needs of all LCMS analyzers on the market
  • The PSA technology with molecular sieves, used in the NiGen series, are drastically reducing the O2 and H2O residual but also the HC presence in the air, offering an extremelly pure nitrogen output (phthalate-free)
  • Built-in compressor oil free including 2 x 50 l. tanks for Compressed Air and Nitrogen
  • Highly reliabile Air compressor with maintenance required only after 16,000 hours of work
  • 2 gas outlets available: UHP Nitrogen and Oil Free Air

Available Models

Technical Specifications

Flow RateNiGen LCMS 40-1 : 38 Nl/min ± 10% a 2000 m asl
Technologies EmployPSA CLAIND
Output Pressure0 – 7 bar/0 – 100 psi ± 3%
Purityup to 99.9%
CompressorOnly in the version 40-1
Air Input CharacteristicsParticulate ≤ 0,01 µm Oil vapors ≤ 0,01 mg/m3 Moisture ≤ 3° C dew point min pressure: 8.5 bar/120 psi max pressure: 10 bar/145 psi
Electrical Supply X Lcms 40-1115 Vac ± 10% 60 Hz 1,9 kW 230 Vac ± 10% 50 Hz 1,6 kW
Index Of ProtectionIP20
Noise< 50 dBA during the stand by of the compressor < 65 dBA with compressor running
Operating Temperature5°C fino 35°C (41°F fino 95°F)
Environmental Humiditymax 90% without condensation
DimensionsHeight: 132 cm/52” Width: 44 cm/17.3” Depth: 110 cm/43.3”
Weight220 kg/489 lbs
Pneumatic ConnectionsCompressed air inlet: G 1/4” female Nitrogen output: G 1/4” female

Key Features 

  • Designed to satisfy the needs of all LCMS analyzers on the market
  • The PSA technology with molecular sieves, used in the NiGen series, are drastically reducing the O2 and H2O residual but also the HC presence in the air, offering an extremelly pure nitrogen output (phthalate-free)
  • Highly reliabile Air compressor with maintenance required only after 14,000 hours of work
  • Able to supply up to 4 LC-MS analysers 
  • 40-1 version with special built-in full oil-free compressor
  • The 50 lt each of air and nitrogen internal storage tanks mean less frequent air compressor starts, hereby reducing noise levels and maintenance
  • CPU with Touch Screen Display allows the monitoring of operational status and menus with report alarms and functioning parameters

Technical Specifications

Flow RateNiGen LCMS 100 : 100 Nl/min ± 10% a 2000 m asl
Technologies EmployPSA CLAIND
Output Pressure0 – 7 bar/0 – 100 psi ± 3%
Purityup to 99.9%
CompressorOnly in the version 40-1
Air Input CharacteristicsParticulate ≤ 0,01 µm Oil vapors ≤ 0,01 mg/m3 Moisture ≤ 3° C dew point min pressure: 8.5 bar/120 psi max pressure: 10 bar/145 psi
Electrical Supply X Lcms 100115/230 Vac ± 10% 60/50 Hz 50 W
Index Of ProtectionIP20
Noise< 50 dBA during the stand by of the compressor < 65 dBA with compressor running
Operating Temperature5°C fino 35°C (41°F fino 95°F)
Environmental Humiditymax 90% without condensation
DimensionsHeight: 132 cm/52” Width: 44 cm/17.3” Depth: 110 cm/43.3”
Weight200 kg/444 lbs
Pneumatic ConnectionsCompressed air inlet: G 1/4” female Nitrogen output: G 1/4” female

Key Features

  • Designed to satisfy the needs of all LCMS analyzers on the market
  • The PSA technology with molecular sieves, used in the NiGen series, are drastically reducing the O2 and H2O residual but also the HC presence in the air, offering an extremelly pure nitrogen output (phthalate-free)
  • Highly reliabile Air compressor with maintenance required only after 14,000 hours of work
  • Able to supply up to 4 LC-MS analysers 
  • The 50 lt each of air and nitrogen internal storage tanks mean less frequent air compressor starts, hereby reducing noise levels and maintenance
  • CPU with Touch Screen Display allows the monitoring of operational status and menus with report alarms and functioning parameters

Key Industries

  • Aerospace
  • Agriculture
  • Automotive
  • Biopharmaceutical and Biotechnology
  • Chemical
  • Construction
  • Cosmetics & Personal Care
  • Defense
  • Die & Mould
  • Education & Academics
  • Electronics
  • Energy
  • Environmental
  • Food & Beverage
  • Luxury
  • Machinery & Manufacturing
  • Medical
  • Mining & Minerals
  • Oil & Gas
  • Optical
  • Paper & Wood
  • Pharmaceutical
  • Polymers, Plastics and Rubbers
  • Powders & Pigments / Coating
  • Railway
  • Semiconductor, Solar & Electronics
  • Service
  • Shipbuilding
  • Textile
  • Wholesale & Retail

test block for Laos

Your download – just a few steps away

Please enter your details here:

test