Binder – Constant Climate Chambers – Series KBF – With large temperature / humidity range
AUSTRALIA
Lauren Benning, Manager, Scientific Solutions
DKSH Australia Pty Ltd
1 Beyer Road
3195 Braeside VIC
AustraliaCAMBODIA
Len Sena, Business Development Manager
DKSH (Cambodia) Ltd
Corner Preah Monivong Boulevard and Street 484
Phnom Penh
CambodiaKOREA
Gyerim Kim, General Manager
DKSH Korea Ltd.
3rd Floor, Zen building, 152 Dogok-ro, Gangnam-gu
06261 Seoul
Korea+82 2 2192 9723
+82 2 2192 9595
LAOS
Julien Moret, General Manager, Laos, Myanmar & Cambodia
DKSH Laos Company Ltd.
3rd Floor, Vientiane Center Office Building Khouvieng Road, Sisattanak District
Vientiane Capital
Laos+856 21 221 023
+856 21 453 555
MYANMAR
Dr. Paing Soe Aung, Assistant General Manager
DKSH (Myanmar) Ltd.
Thitsar Road, Yankin Township
Yangon
MyanmarNEW ZEALAND
Benoit Fissot, General Manager, Technology, Australia & New Zealand
DKSH New Zealand Limited
33 Westpoint Drive
0618 Hobsonville, Auckland
New ZealandTHAILAND
Oliver Hammel, Vice President
DKSH Technology Limited (Head Office)
2533 Sukhumvit Road, Bangchak, Phrakhanong
10260 Bangkok
ThailandVIETNAM
Phuong ThiQuynh Ngo, Manager
DKSH Technology
16th Floor, Peakview Tower. 36 Hoang Cau Street,
O Cho Dua Ward, Dong Da District
10000 Ha Noi
Vietnam
KBF series Brochure – Binder
KBF 115 Datasheet – Binder
KBF 240 Datasheet – Binder
KBF 720 Datasheet – Binder
KBF 1020 datasheet – Binder
The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate conditions. From programming to documentation, this humidity test chamber meets all critical requirements.
Key Features
- Homogeneous climate conditions thanks to APT.line™ technology
- Automatic water and wastewater management
- Pressure humidification with fast response times
Technical Specifications
Model | Housing dimensions not incl. fittings and connections W x H x D | Internal dimension W x H x D | Net weight | Interior volume |
KBF 115 | 880 x 1050 x 650 mm | 600 x 483 x 351 mm | 128 kg | 102 L |
KBF 240 | 925 x 1460 x 800 mm | 650 x 785 x 485 mm | 189 kg | 247 L |
KBF 720 | 1250 x 1925 x 890 mm | 973 x 1250 x 576 mm | 312 kg | 700 L |
KBF 1020 | 1250 x 1925 x 1145 mm | 976 x 1250 x 836 mm | 379 kg | 1020 L |
Available Models

Technical Specifications
Max. heat compensation at 40 °C [W] | 200 |
Temperature fluctuation [± K] | 0.1 |
---|---|
Temperature range | 0…70 |
Power frequency [Hz] | 50/60 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Depth net [in] | 25.61 |
Height net [in] | 41.4 |
Width net [in] | 34.67 |
- Temperature range: 0 °C to 70 °C
- Humidity range: 10 % to 80 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Intuitive touchscreen controller with time-segment and real-time programming
- BINDER Multi Management Software APT-COM™ Basic Edition
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- Inner chamber made of stainless steel
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating

Technical Specifications
Max. heat compensation at 40 °C [W] | 300 |
Temperature fluctuation [± K] | 0.1 |
---|---|
Temperature range | 0…70 |
Power frequency [Hz] | 50/60 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Depth net [in] | 31.52 |
Height net [in] | 57.5 |
Width net [in] | 36.45 |
- Temperature range: 0 °C to 70 °C
- Humidity range: 10 % to 80 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Intuitive touchscreen controller with time-segment and real-time programming
- BINDER Multi Management Software APT-COM™ Basic Edition
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- Inner chamber made of stainless steel
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- 4 stable castors, two with brakes, from 240 liters
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating

Technical Specifications
Max. heat compensation at 40 °C [W] | 600 |
Temperature fluctuation [± K] | 0.1 |
---|---|
Temperature range | 0…70 |
Power frequency [Hz] | 50/60 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Depth net [in] | 35.07 |
Height net [in] | 75.8 |
Width net [in] | 49.3 |
- Temperature range: 0 °C to 70 °C
- Humidity range: 10 % to 80 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Intuitive touchscreen controller with time-segment and real-time programming
- BINDER Multi Management Software APT-COM™ Basic Edition
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- Inner chamber made of stainless steel
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- 4 stable castors, two with brakes, from 240 liters
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating

Technical Specifications
Max. heat compensation at 40 °C [W] | 600 |
Temperature fluctuation [± K] | 0.5 |
---|---|
Temperature range | 0…70 |
Power frequency [Hz] | 50/60 |
Rated Voltage [V] | 200…240 |
Unit fuse [A] | 16 |
Depth net [in] | 45.1 |
Height net [in] | 75.8 |
Width net [in] | 49.3 |
- Temperature range: 0 °C to 70 °C
- Humidity range: 10 % to 80 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Intuitive touchscreen controller with time-segment and real-time programming
- BINDER Multi Management Software APT-COM™ Basic Edition
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- Inner chamber made of stainless steel
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- 4 stable castors, two with brakes, from 240 liters
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating
BINDER Constant Climate Chambers
You are currently viewing a placeholder content from Default. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationKey Industries
- Education & Academics
- Food & Beverage
- Pharmaceutical
- Service